1 /*
2 * Copyright (c) 2005 The University of Notre Dame. All Rights Reserved.
3 *
4 * The University of Notre Dame grants you ("Licensee") a
5 * non-exclusive, royalty free, license to use, modify and
6 * redistribute this software in source and binary code form, provided
7 * that the following conditions are met:
8 *
9 * 1. Redistributions of source code must retain the above copyright
10 * notice, this list of conditions and the following disclaimer.
11 *
12 * 2. Redistributions in binary form must reproduce the above copyright
13 * notice, this list of conditions and the following disclaimer in the
14 * documentation and/or other materials provided with the
15 * distribution.
16 *
17 * This software is provided "AS IS," without a warranty of any
18 * kind. All express or implied conditions, representations and
19 * warranties, including any implied warranty of merchantability,
20 * fitness for a particular purpose or non-infringement, are hereby
21 * excluded. The University of Notre Dame and its licensors shall not
22 * be liable for any damages suffered by licensee as a result of
23 * using, modifying or distributing the software or its
24 * derivatives. In no event will the University of Notre Dame or its
25 * licensors be liable for any lost revenue, profit or data, or for
26 * direct, indirect, special, consequential, incidental or punitive
27 * damages, however caused and regardless of the theory of liability,
28 * arising out of the use of or inability to use software, even if the
29 * University of Notre Dame has been advised of the possibility of
30 * such damages.
31 *
32 * SUPPORT OPEN SCIENCE! If you use OpenMD or its source code in your
33 * research, please cite the appropriate papers when you publish your
34 * work. Good starting points are:
35 *
36 * [1] Meineke, et al., J. Comp. Chem. 26, 252-271 (2005).
37 * [2] Fennell & Gezelter, J. Chem. Phys. 124, 234104 (2006).
38 * [3] Sun, Lin & Gezelter, J. Chem. Phys. 128, 24107 (2008).
39 * [4] Kuang & Gezelter, J. Chem. Phys. 133, 164101 (2010).
40 * [5] Vardeman, Stocker & Gezelter, J. Chem. Theory Comput. 7, 834 (2011).
41 */
42
43 #ifndef UTILS_PHYSICALCONSTANTS_HPP
44 #define UTILS_PHYSICALCONSTANTS_HPP
45
46 namespace OpenMD {
47
48 namespace PhysicalConstants {
49 const RealType kb = 1.9872156E-3; // boltzman's constant in kcal/(mol K)
50 const RealType kB = 8.31451e-7; // boltzmann constant amu*Ang^2*fs^-2/K
51 const RealType energyConvert = 4.184E-4; // convert kcal/mol -> (amu A^2)/fs^2
52 const RealType rotationalEnergyConvert = energyConvert*2.0*M_PI;
53
54 const RealType pressureConvert = 1.63882576e8; // converts amu*fs^-2*Ang^-1 -> atm
55
56 /*
57 * surfaceTensionConvert
58 * multiplies standard input file units of
59 * surfaceTension (Newton / meter)
60 * returns values of
61 * kcal mol^-1 Angstrom^-2
62 */
63 const RealType surfaceTensionConvert = 1.439326479; // convert N/m to kcal/mol*Ang^-2
64
65 /*
66 * viscoConvert
67 * used for products of:
68 * viscosity (Poise) * distance (Angstroms) * velocity (Angstrom / fs)
69 * returns values of:
70 * force in (kcal mol^-1 Angstrom^-1)
71 */
72 const RealType viscoConvert = 1.439326479e4;
73
74 /*
75 * thermalConductivityConvert
76 * multiplies standard input file units of
77 * themalConductivity (watts meter^-1 Kelvin^-1)
78 * returns values of:
79 * kcal mol^-1 Angstrom^-1 fs^-1 Kelvin^-1
80 */
81 const RealType thermalConductivityConvert = 1.439326479e-5;
82
83 const RealType bohrToAngstroms = 1.8897161646320724;
84 const RealType angstromsToBohr = 0.52918;
85 }